Lightning Arrester

Backed by our rich industry experience, we make available a wide gamut of Lightning Protection System. These systems are extensively utilized for safeguarding commercial and other buildings against the adverse effects of lightning. Characterized by flawless designs, this range is highly appreciated by the customers.
Request CallBack
External Lightning Protection System
Get Best Quote
Approx.
Rs 70,000
Per Unit

External Lightning Protection System

Product Details:
Lightning impulse current (10/350)50 KA Iimp
Nominal discharge current (8/20)50 KA In
Response time TaLess than 100ns
Follow current interrupting rating at Uc25 KA Ifi
Max. back-up fuse500 AgL/gG

In normal conditions there is in the atmosphere a balance between positive and negative charges, where the ground is more negatively charged than the air and the elements placed on the ground.

 

However, the formation of storm clouds creates a charge polarization: usually, the lower part of the cloud is charged negatively, inducing then a positive charge at the ground and other elements on it. The electric field at the atmosphere can reach then 10s of kilovolts.

 

This positive charge becomes more evident at metallic elements, pointed objects and well-earthed objects, including trees.

 

When the electric field is high enough, the cloud starts discharging towards the ground. The path formed by this discharge is called “downward leader” and produces a very sharp variation of the electric field, causing then corona effect.

 

One of these objects will be the one forming the upward leader, which will move towards the downward leader thus forming the discharge path between the cloud and the ground. This object will receive the lightning strike. The cloud charge will search the straightest path to earth. If this path is not controlled, damages can be severe.

 

Electrical effects: equipment destruction. Ground voltage rises and surges can damage all the equipment connected to the electrical network.

(1) Electrodynamical effects: Building damages. Conductors are submitted to mechanical strengths for being placed inside a magnetic field originated in another conductor. They may cause deformations and rupture.

(2)Thermal effects: Fires. Heat dissipation by Joule effect can even cause fires.

(3) Effects on living beings: electrocutions and burns. Currents passing through during a short lapse are enough for electrocution risk by respiratory or cardiac arrest. Further burn risk appears. (4) Induction effects: within a variable electromagnetic field, induced currents appear in every conductor. If these conductors are connected to computers or other electronic equipment, damages can be severe. The consequences of all these effects are important economical losses because of the damages in buildings and equipment due to lightning strike or fires caused by a discharge. Costs can be also very high if lightning causes service interruptions, stops production processes or forces to switch off and on again certain machinery if the control equipment is affected by lightning. Waveshape and currents for positive (ground to cloud) and negative (cloud to ground) discharges. In normal conditions there is in the atmosphere a balance between positive and negative charges, where the ground is more negatively charged than the air and other elements on the ground. However, the formation of storm clouds creates a charge polarization: usually, the lower part of the cloud is charged negatively, inducing then a positive charge at the ground and other elements on it. The electric field at the atmosphere can then reach tens of kilovolts. This positive charge is more evident at metallic elements, pointed objects and well-earthed objects, including trees. When the electric field is high enough, the cloud starts discharging towards the ground. The path formed by this discharge is called the “downward leader” and produces a very sharp variation in the electric field, causing the corona effect. One of these objects will be the one forming the upward leader, which will move towards the downward leader thus forming the discharge path between the cloud and the ground. This object will receive the lightning strike. The cloud charge will find the most direct path to earth. If this path is not controlled, damages can be severe.


Yes! I am Interested
Request CallBack
LPI Lightning Protection System
Ask For Price

LPI Lightning Protection System

Product Details:
BrandLPI
Lighting Protection MaterialCopper, Copper-Clad Steel, Aluminum
System IncludeLightning Rod, Lightning Arresters, Lighting Recorder etc.
LPI Lightning Protection System & the need of safety lightning is one of the most devastating natural phenomena. There are many discharges during lightning storms and some of them caneven reach hundreds of kilo amperes. The electrical discharges are a great hazard to people, animal, buildings and electronic equipments. The economic consequences of lightning are also very important; it can cause fire, stop production of a factory or interrupt critical processes. A direct lightning discharge lasts a very short time but the intensity is enough to provoke electrocution resulting in heart failure andcausing burns of different degrees to the human beings. Lightning is a constant hazard where the buildings and equipments are becomingmore complex and sensitive every day. One lightning strike discharge can damage the buildings and cause failures to the electronic devicesinside the building and sometimes it may even results in fire and important economical losses.Until now, there is no device that can prevent lightning formation or lightning strikes. However, it is possible to create a path (divert) forthe lightning discharge to the ground which will minimise the damage to the environment through a well designed Lightning ProtectionSystem (LPS).

Features:

  • No external power required
  • No moving parts
  • Non radioactive technology

Yes! I am Interested
Request CallBack
HS 100 Lightning Arresters
Get Best Quote
Approx.
Rs 3,200
Per Unit

HS 100 Lightning Arresters

Product Details:
Arrester TypeStation Type, Intermediate Type, Distribution Type
BrandHakel
Weight360g
Lifetimemin. 100 000 h
Method of assemblyDIN rail 35 mm
ModelHS 100

HS100 and JK110 are the total current spark gaps type 1 according to EN 61643-11 and IEC 61643-11. These are recommended for use in the Lightning Zones Concept at the boundaries of LPZ 0 – 1 (according to IEC 1312-1 and EN 62305), where they provide the equipotential bonding and discharge of both, the lightning current and the switching surge, which are generated in power supply systems entering the building. The lightning arresters are constructed as the encapsulated, non-exhaust, multiple spark gaps, which do not have any special requirements for installation in the main switchboards in terms of the gas exhaustion generated during the passage of the lightning current.

 

They are intended for use in TN-S and TT systems. HS100 and JK110 are to be installed only between N and PE in modifications of 3+1 or 1+1.


Yes! I am Interested
View PDF
Request CallBack
ESE Lightning Arrester
Get Best Quote
Approx.
Rs 90,000
Per Piece

ESE Lightning Arrester

Product Details:
Arrester TypeStation Type, Intermediate Type, Distribution Type
ESE Lightning Arrester the LPI Stormaster (Early Streamer Emission) range of terminals provides a safe and efficient system for the protection of your facility from direct lightning strikes. The LPI Stormaster ESE terminal captures the lightning energy at a preferred point.

Working of ESE Lightning Arrester:

  • The Stormaster ESE air terminal uses the naturally occurring electrical field to complete the timely release of an upwardstreamer.
  • This process provides for a safe and efficient method of controlling dangerous lightning energy at a preferred point.
  • As a thunderstorm gathers overhead, the ambient electrical field surrounding the Stormaster ESE begins to rise involtage.
  • Upon the approach of a downward leader towards the protected area, there is a rapid increase in the electric field which initiates the triggering of an upward streamer from the Stormaster ESE terminal.
  • The early initiation allows for a larger or enhanced area of protection to be provided by the Stormaster ESE in comparison to a conventional rod, in accordance with NF C 17-102 (2011).
  • With the release of the upward streamer from the finial tip earlier than other competing structural points, the Stormaster ESE terminal becomes a preferred point for the capture of the lightning discharge within the protected area.

Certified Performance:

  • As one of the leading companies in the field of lighting protection, LPI has invested heavily in field and laboratorytesting as part of its ongoing commitment to research and development.
  • Throughout the product development of the Stormaster ESE the proto-type models were subjected to intense testing under high voltage conditions.
  • Following further refinements the Stormaster terminals were subjected to final testing by an independently accredited test laboratory which completed testing in full compliance with the French National Standard NF C 17-102 (2011).
  • The final testing of Stormaster ESE terminals showed effective performance as defined in this Standard. LPI Stormaster ESE lightning air terminal is tested & certified from CPRI (Central Power Research Institute),Bangalore, Government of India.

    Additional Information:
    • Item Code: Stormaster
    Yes! I am Interested
    Request CallBack
    ESE Lightning Arrester
    Get Best Quote
    Approx.
    Rs 90,000
    Per Unit

    ESE Lightning Arrester

    Product Details:
    Material Pure Copper or Copper Coated Stainless Steel
    Current gradient less than 5KA
    Grounding resistanceless than 10 ohm
    Resistible wind speedover 50m/s
    The protection radius (Rp) of a Stormaster ESE terminal is calculated using the following formula as defined in NF C 17-102 (September 2011), namely:
    Rp(h) = √2rh − h2 + (2r + ) for h ≥ 5 m and Rp = h x Rp5 / 5 for 2 ≤ h < 5 m where h = Stormaster height relative to the area being protected (m) Rp5 = value of Rp from Eqn. (1) when h = 5 m r = 20 m for protection level I (Very High protection) 30 m for protection level II (High protection) 45 m for protection level III (Medium protection) 60 m for protection level IV (Standard protection) and = Stormaster time and height advantage according to the Stormaster model installed: Choices: Stormaster ESE 15 SS: = 15 μs Stormaster ESE 30 SS: = 30 μs Stormaster ESE 50 SS: = 50 μs Stormaster ESE 60 SS: = 60 μs

    Yes! I am Interested
    Request CallBack
    SPC PV 600 DS Lightning Arresters
    Get Best Quote
    Approx.
    Rs 3,900
    Per Unit

    SPC PV 600 DS Lightning Arresters

    Product Details:
    BrandHakel
    ColorBlue
    SeriesSPC PV 600 DS
    PIV is lightning arrester type 1 according to EN 61643-11 and IEC 61643-1. These arresters are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0 – 1 (according to IEC 1312-1 and EN 62305) for lightning current equipotential bonding and elimination of switching surges that originate in power supply systems entering the building. The PIV is mainly intended for use in TNC systems. For TNS and TT systems it is necessary to combine these arresters with lightning arrester B25, B50 or B80 which are intended for equipotential bonding between N and PE.
    The main use of PIV12,5 arrester is in structures of LPL III – IV according to EN 62305, e.g. residential houses with cable supply and subdistribution boards of big industrial structures.

    Function of remote monitor terminals:
    • When the PIV DS is operating correctly, the terminations 1-2 are connected to normally closed contacts, 2-3 are normally open. If the internal varistor component is damaged as a result of thermal overloading, terminations 1-2 will then be open and 2-3 closed.

    Yes! I am Interested
    Request CallBack
    HS 50 -50 Surge Arrester
    Get Best Quote
    Approx.
    Rs 3,500
    Per Unit

    HS 50 -50 Surge Arrester

    Product Details:
    Minimum Order Quantity1 Unit
    ClassificationType B, Type C, Type D
    Poles Number1 Pole, 1pole+N, 3 Pole, 3 Pole+N
    Highest continuous operating voltage U C440 IN
    Max. impulse current (10/350) I imp50 kA
    Voltage protection level U pLess than 2.5 kV
    Maximum foreclosure500 AgL / gG

    The HS55 lightning arrester is designed for special installations in industrial buildings where a permanent operating voltage with a maximum value of 440 V AC is required. It is installed in the main switchboards of large industrial buildings and where the direct lightning strike is in danger.


    Yes! I am Interested
    View PDF
    Request CallBack
    SPC PV 1000 DS Lightning Arresters
    Get Best Quote
    Approx.
    Rs 10,200
    Per Unit

    SPC PV 1000 DS Lightning Arresters

    Product Details:
    BrandHakel
    ColorBlue
    Weight900 g
    Lifetimemin.100 000 h
    Degree of protection of enclosureIP 20
    SPC PV 1000 DS Lightning Arresters type 1+2 according to EN 61643-11. It is designed for protection of positive and negative busbars of photovoltaic systems against the surge effects. These arresters are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0-1 (according to IEC 1312-1and EN 62305). Particular varistor sectors connected between terminals L+, L- and PE are equipped with fitted internal disconnectors which are activated when varistors fail (overheat). Failure indication of these disconnectors is partly mechanical (by red signaling target) and partly remote monitoring (by potential free switching contacts).

    Function of remote monitor terminals:
    • When the SPC PV DS is operating correctly, the terminations 1-2 are connected to normally closed contacts, 2-3 are normally open. If the internal varistor component is damaged as a result of thermal overloading, terminations 1-2 will then be open and 2-3 closed.

    Yes! I am Interested
    Request CallBack
    High Voltage Shielded Cable
    Get Best Quote
    Approx.
    Rs 3,800
    Per Meter

    High Voltage Shielded Cable

    Product Details:
    overall diameterApprox 36 mm
    Withsatnd Voltage500KV
    Impedence18 Ohm
    Capcitance285pF/m
    Inductance93nH/m
    HVSC Plus is a concentric conductor designed with special features to handle lightning transients. The key features of the design can be summarised as follows: Use of a cylindrical filler material to produce an “annular” design for the inner conductor. This design is optimised for carrying high-frequency or transient currents, namely lower inductance and allowance for the “Skin effect”. Furthermore, the cross-sectional area of the inner conductor is large enough to be completely compliant with all international standards for lightning protection [1-4]; An insulation layer of sufficient thickness to withstand voltages of a pre-specified level, surrounded by thin semiconductive “stress-control” layers applied during a “triple extrusion” manufacturing process; A conductive, copper-tape outer screen layer that provides screening of electric fields; A rugged PVC outer sheath or jacket to protect the cable during installation and in-service period; Performance independent of the type of structure on which it is installed, e.g., metallic, masonry, non-conductive, etc.

    The voltage within the cable is divided across two known geometries, namely between the inner conductor and the screen, and between the screen and the structure. These voltages are controlled through knowledge of the main cable parameters, viz., impedance, inductance, capacitance and phase velocity. The HVSC Plus cable design is shown in Figure 1. From the inside to the outside, the components are as follows:
    (i) Solid, cylindrical, polyethylene filler;
    (ii) Inner conductor comprised of copper strands (XSA 70 mm2); (iii) Binder tape;
    (iv) Semiconductive stress-relief layer (“conductor screen”)
    (v) Polyethylene insulation (approx. 5 mm thick);
    (vi) Semiconductive stress-relief layer (“insulation screen”)
    (vii) Copper tape main screen;
    (viii) PVC outer sheath.
    The cable has an overall diameter of approximately 36 mm. The typical installation practice for the cable can be summarised as follows. The cable must be: Correctly terminated at the upper end – specific cut lengths of the various layers and then the application of a high-voltage termination kit (see installation guide); Electrically shorted (inner-to-screen connection) at the bottom end and bonded to the base of the structure; Installed in such a way as to not infringe on the minimum bend radius criterion.

    Yes! I am Interested
    Request CallBack
    Copper Lightning Arrester
    Get Best Quote
    Approx.
    Rs 3,500
    Per Unit

    Copper Lightning Arrester

    Product Details:
    ClassB
    Number Of Poles4.0
    PhaseSingle Phase
      Our organizations have successfully expanding its business in the market by offering quality assured array of Copper Lightning Arrester.

        Yes! I am Interested
        Request CallBack
        Lightning Arrestor
        Get Best Quote
        Approx.
        Rs 90,000
        Per Unit

        Lightning Arrestor

        Product Details:
        Arrester TypeIntermediate Type
        Housing TypePolymer
        MaterialCopper
        Uc120
        Reated Voltage10kV
        Yes! I am Interested
        Request CallBack
        Hakel B100 Lightning Arrester
        Get Best Quote
        Approx.
        Rs 3,900
        Per Unit

        Hakel B100 Lightning Arrester

        Product Details:
        BrandHakel
        ModelHakel B 100
        SystemTNS, TT, IT
        EngagementN / PE
        Degree of protectionIP 20
        EnvironmentBasic
        The method of installationDIN rail 35mm
        Material of housingSLOVAMID 6FRC2
        Mass210 g
        B25, B25M, B50, B80 and B100 are additive arresters Type 1 according to EN 61643-11. Designation M - specifies the type of construction with removable module. They are used in TN-S and TT, and at the boundaries of LPZ 0 and 1 It is installed between N and PE conductor in connections 3 +1 or 1 +1.

        Yes! I am Interested
        Request CallBack
        Lightning Arresters for Offices and Family Houses
        Ask For Price

        Lightning Arresters for Offices and Family Houses

        Product Details:
        Arrester TypeStation Type, Intermediate Type, Distribution Type

        Lightning Arresters for Offices and Family Houses this era brings the need to use a lot of equipment and appliances which already contain sensitive electronics. This makes life easier and allows more comfortable control of equipment. But many of us underestimate the danger of lightning stroke and overvoltage which can arise in a separate building. But even an object protected against direct lightning stroke can not ensure that induced surge will not damage sensitive electronics that controls the expensive appliances. Therefore, it is necessary to realize the need of protection of all sensitive electronic equipment used in offices and homes. HAKEL offers plenty of protection solutions against lightning and overvoltage. Lightning arresters PIVM12,5, which are installed in the main switchboard, then a surge protector, which is an integral part of every secondary switchboards PIIIM. For a complete security of all electronic devices it is necessary to install an arrester with high frequency filter as close as possible to the protected equipment. For these purposes, HAKEL offers an arrester with high-frequency filters PI-k (single-phase connection) and PI-3k (three-phase connection). When the propounded arresters are used properly we can exclude a break-down of purchased expensive sensitive equipment.

        TN-C

        TN-S


        Yes! I am Interested
        Request CallBack
        Stormaster Lightning Arresters
        Get Best Quote
        Approx.
        Rs 60,000
        Per Unit

        Stormaster Lightning Arresters

        Product Details:
        Arrester TypeStation Type, Intermediate Type, Distribution Type
        MaterialStainless Steel
        Weight6.0kg
        The LPI Stormaster (Early Streamer Emission) range of terminals provides a safe and efficient system for the protection of your facility from direct lightning strikes. The LPI Stormaster ESE terminal captures the lightning energy at a preferred point.

        How does the LPI Stormaster ESE Terminal work?

        The Stormaster ESE air terminal uses the naturally occurring electrical field to complete the timely release of an upward streamer. This process provides for a safe and efficient method of controlling dangerous lightning energy at a preferred point.As a thunderstorm gathers overhead, the ambient electrical field surrounding the Stormaster ESE begins to rise in voltage. Upon the approach of a downward leader towards the protected area, there is a rapid increase in the electric field which initiates the triggering of an upward streamer from the Stormaster ESE terminal. The early initiaton allows for a larger or enhanced area of protection to be provided by the Stormaster ESE in comparison to a conventional rod, in accordance with NF C 17-102 (2011).

        With the release of the upward streamer from the finial tip earlier than other competing structural points, the Stormaster ESE terminal becomes a preferred point for the capture of the lightning discharge within the protected area.
        Certified Performance
        As one of the leading companies in the field of lightning protection, LPI has invested heavily in field and laboratory testing as part of its on-going commitment to research and development.Throughout the product development of the Stormaster ESE, the proto-type models were subjected to intense testing under high voltage conditions. Following further refinements, the Stormaster terminals were subjected to final testing by an independently accredited test laboratory which completed testing in full compliance with the French National Standard
        NF C 17-102 (2011). The final testing of Stormaster ESE terminals showed effective performance as defined in this Standard. Lightning Protection International Pty Ltd (LPI) is a fully Australian owned manufacturer and supplier of direct strike lightning protection, transient voltage surge suppression, and earthing / grounding solutions. For many years, LPI have been providing specialist lightning protection advice to customers in some of the most lightning prone areas of the world. Our personnel have extensive experience in risk management, system design, training, installation, certification, and commissioning of systems in a wide variety of industry groups. LPI maintains a third party Quality Management System to AS/NZS ISO 9001:2008. LPI’s range of products and services are exported from its head office and research facility (in Tasmania, Australia) and via regional offices worldwide. The company has been recognised within Australia for its outstanding export successes and has been awarded several prestigious export awards.

        Yes! I am Interested
        Request CallBack
        Conventional Lightning Protection System As per IEC62305
        Get Best Quote
        Approx.
        Rs 2,000
        Per Unit

        Conventional Lightning Protection System As per IEC62305

        Product Details:
        Minimum Order Quantity1 Unit
        BrandLPI
        Lighting Protection MaterialCopper, Copper-Clad Steel
        System Includeair terminals, bases, conductors, connectors and fasteners etc.
        Lightning is one of the most devastating natural phenomena. There are many discharges during lightning storms and some of them can even reach hundreds of kiloamperes.

        These electrical discharges are a great hazard to people, animals, buildings and electronic equipment. The economic consequences of lightning are also very important; it can cause fire, stop production of a factory or interrupt critical processes. A direct lightning discharge to a person results in current flowing through the body. This current lasts a very short time but the intensity is enough to provoke electrocution resulting in heart failure and causing burns of different degrees.

        Until now, there is no device that can prevent lightning formation. However, it is possible to create a path for the discharge to ground of lightning that minimizes damage on the environment: the Lightning Protection System.

        The need for lightning protection should be considered preferably during the first phases of the structures design. A Lightning Protection System has 4 basic objectives: 1) Capture lightning. 2) Conduct lightning current to earth avoiding damage. 3) Disperse lightning current in the ground quickly and safely. 4) Avoid the secondary effects of lightning (overvoltages).

        Yes! I am Interested
        Request CallBack
        Spark Gap Lightning Arrester
        Get Best Quote
        Approx.
        Rs 3,500
        Per Unit

        Spark Gap Lightning Arrester

        Product Details:
        Arrester TypeStation Type, Intermediate Type, Distribution Type
        BrandHakel
        IP RatingIP 20
        ModelB 100

        HS100i is a Spark Gap Lightning Arrester 1 and class I according to EN 61643-11 and IEC 61643-1. These are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0 to 2 (according to IEC 1312-1 and EN 62305) for lightning current equipotential bonding in power supply systems entering the building. Type 1 lightning current arresters are used for lightning protection equipotential bonding to VDE 0185-305 (IEC 62305). The lightning current arresters are constructed as an encapsulated spark gap technology for installation in main switchboards. For TNS and TT systems it is necessary to combine these arresters with lightning current arrester HS50-50i which is recommended for equipotential bonding between N and PE. The main use of HS100i is in industrial installations such as transformers, the main switchboards of large industrial buildings and places with high risk of a direct lightning strike and with an external lightning protection of the highest class I to IV. It is also suitable for applications in unmeasured parts of electrical installation.


        Yes! I am Interested
        Request CallBack
        PIIIM PV 1000 Lightning Arrester
        Get Best Quote
        Approx.
        Rs 7,500
        Per Unit

        PIIIM PV 1000 Lightning Arrester

        Product Details:
        SeriesPIIIM PV 1000
        Failure signalisationGreen - Ok / Red - Failure
        PIV is lightning arrester type 1 according to EN 61643-11 and IEC 61643-1. These arresters are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0 – 1 (according to IEC 1312-1 and EN 62305) for lightning current equipotential bonding and elimination of switching surges that originate in power supply systems entering the building. The PIV is mainly intended for use in TNC systems. For TNS and TT systems it is necessary to combine these arresters with lightning arrester B25, B50 or B80 which are intended for equipotential bonding between N and PE.

        The main use of PIV12,5 arrester is in structures of LPL III – IV according to EN 62305, e.g. residential houses with cable supply and subdistribution boards of big industrial structures.

        Yes! I am Interested
        Request CallBack
        CSE Lightning Arresters
        Ask For Price

        CSE Lightning Arresters

        Product Details:
        Arrester TypeStation Type, Intermediate Type, Distribution Type
        BrandLPI
        Lighting Protection MaterialCopper
        PIV is Lightning Arresters type 1 according to EN 61643-11 and IEC 61643-1. These arresters are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0 – 1 (according to IEC 1312-1 and EN 62305) for lightning current equipotential bonding and elimination of switching surges that originate in power supply systems entering the building. The PIV is mainly intended for use in TNC systems. For TNS and TT systems it is necessary to combine these arresters with lightning arrester B25, B50 or B80 which are intended for equipotential bonding between N and PE. The main use of PIV12,5 arrester is in structures of LPL III – IV according to EN 62305, e.g. residential houses with cable supply and sub distribution boards of big industrial structures.

        Yes! I am Interested
        Request CallBack
        Lightning Arresters
        Get Best Quote
        Approx.
        Rs 5,000
        Per Unit

        Lightning Arresters

        Product Details:
        Arrester TypeStation Type
        BrandHakel
        Housing TypePorcelain
        Weight900 g
        Lifetimemin.100 000 h
        We are considered in the market to be one of the leading manufacturers and suppliers of this highly commendable range of Lightning Arrester.

        Yes! I am Interested
        Request CallBack
        Hakel 30101 P-3k 400
        Get Best Quote
        Approx.
        Rs 3,600
        Per Unit

        Hakel 30101 P-3k 400

        Product Details:
        Arrester TypeDistribution Type
        BrandHakel
        Housing TypePorcelain
        Yes! I am Interested
        Request CallBack
        HakelZIL- HZ110  Lightning Arrester
        Get Best Quote
        Approx.
        Rs 3,900
        Per Unit

        HakelZIL- HZ110 Lightning Arrester

        Product Details:
        Arrester TypeStation Type, Intermediate Type, Distribution Type
        Weight1000 g
        Lifetimemin. 100 000 h
        Method of assemblyholder SP50U10
        Degree of protection of enclosureIP00

        HZ110 is a lightning arrester type 1 according to EN 61643-11 and IEC 61643-11. This is recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0 – 1 (according to IEC 1312-1 and EN 62305), where it provides the equipotential bonding and discharge of both, the lightning current and the switching surge, which are generated in power supply systems entering the building. The lightning arrester is constructed as an encapsulated, non-exhaust, multiple spark gap, which does not have any special requirements for installation in the main switchboards in terms of the gas exhaustion generated during the passage of the lightning current. HZ110 is mainly intended for use in the power lines, which are operated as a system TN-C.


        Specifications:
        • PIV is lightning arrester type 1 according to EN 61643-11 and IEC 61643-1. These arresters are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0 – 1 (according to IEC 1312-1 and EN 62305) for lightning current equipotential bonding and elimination of switching surges that originate in power supply systems entering the building.
        • The PIV is mainly intended for use in TNC systems. For TNS and TT systems it is necessary to combine these arresters with lightning arrester B25, B50 or B80 which are intended for equipotential bonding between N and PE.
        • The main use of PIV12,5 arrester is in structures of LPL III – IV according to EN 62305, e.g. residential houses with cable supply and subdistribution boards of big industrial structures.

        Yes! I am Interested
        View PDF
        Request CallBack
        LPI Inline Coupling Unit
        Get Best Quote
        Approx.
        Rs 18,500
        Per Unit

        LPI Inline Coupling Unit

        Product Details:
        Inline Coupling MaterialCast aluminium
        Cast aluminium550 mm x 150 mm x 120 mm
        Weight2.7 kgs
        Anchoring points3 max
        clamping torque55 kg/cm
        LPI Inline coupling is a purpose-designed coupling which enables clamping of the FRP mast to the aluminium lower mast. The inline coupling provides 3 guy anchoring points and provides an exit point for the HVSC Plus.

        Yes! I am Interested
        Request CallBack
        Lightning Arrester
        Get Best Quote
        Approx.
        Rs 4,300
        Per Unit

        Lightning Arrester

        Product Details:
        BrandHakel
        MaterialBrass/Copper
        Average discharge current Less than 7KA
        Grounding resistance Less than 10 ohm
        Resistible wind speed Over 50m/s
        A structural Lightning Arrester is designed to protect the fabric of a structure and the lives of people inside by channelling lightning strike energy in a safe and controlled manner to the earth termination network. Hakel structural lightning protection employs air termination components and down conductors - air rods, bases, conductors and clips - to create an effective barrier against lightning. This approach follows the Faraday Cage principle of lightning protection, as advocated by the majority of national and international standards.

        Hakel has been manufacturing in accordance with international standards resulting in high quality of products and accurate production. Many standards related to earthing & lightning system are published for appropriate uses such as design, material specification, supply & installation.

        Yes! I am Interested
        Request CallBack
        Lightning Protection System
        Get Best Quote
        Approx.
        Rs 90,000
        Per Unit

        Lightning Protection System

        Product Details:
        BrandLPI
        Lighting Protection MaterialCopper, Copper-Clad Steel, Aluminum
        System IncludeLightning Arrester, Lightning Rod, Lighting Recorder, Shielded Cable etc.
        As one of the leading companies in the field of lightning protection, LPI has invested heavily in field and laboratory testing as part of its ongoing commitment to research and development. Throughout the product development of the Stormaster ESE, the proto-type models were subjected to intense testing under high voltage conditions. Following further refinements, the Stormaster terminals were subjected to final testing by an independently accredited test laboratory which completed testing in full compliance with the French National Standard NF C 17-102 (2011). The final testing of Stormaster ESE terminals showed effective performance as defined in this Standard.

        Yes! I am Interested
        Request CallBack
        Lightning Arresters
        Get Best Quote
        Approx.
        Rs 3,350
        Per Unit

        Lightning Arresters

        Product Details:
        Arrester TypeStation Type, Intermediate Type, Distribution Type
        BrandLPI
        MaterialCopper
        Specifications:
        • Type DTB 485 /R Number of protected pairs 1 Nominal voltage UN 6 V AC
        • Max. continuous operating voltage UC 7,2 V AC
        • Nominal current IN 0,1 A C2 Max. discharge current (8/20) Imax 2 kA Voltage protection level at In Up 15 V Voltage protection level at 1kV/μs UP 9 V Article number 41785

        Yes! I am Interested
        Request CallBack
        Lightning Counter
        Get Best Quote
        Approx.
        Rs 17,000
        Per Unit

        Lightning Counter

        Product Details:
        ModelLSR-I
        Arrester TypeStation Type, Intermediate Type, Distribution Type
        Senstivity1500A
        LPI Lightning Strike Recorder (LSR1) is a lightning strike counter. The LSR1 is simply mounted at any location along the down conductor route. Its purpose is to record the number of strikes captured and conveyed by the downconductor. When the lightning rod receive an impact of the lightning strike, discharge counter detects the energy dissipated by the down conductor, thereby incrementing the number. The LSR1 operates by sensing current by means of an inductive pick up loop. With the voltage impulse detected by the current transformer (CT) a trigger to the pulse counter then turns the counter to register the lightning event. The equipment does not require either external or internal power supply, as it is electromechanical and uses the power of the induced current dissipated through the down conductor.

        Features:
        • 7 Digits Up to 9,999,999 counts IP 67 enclosure Testable using LSR-Tester
        • Ordering Code LSR1

        Description
        • Lightning strike recorder
        • Current sensitivity 1500 A 8/20 μs impulse
        • Operating range Min. 1500 A and Max. 220 kA 8/20 μs
        • Display Mechanical 7 digits display (not re-settable)
        • Dimension 100 mm (B) x 100 mm (H) x 55 mm (D)
        • Weight 0.57 kg
        • Mounting Releasable UV resistant plastic cable ties suitable for up to ø40 mm cable or 50 x 5 mm flat tape
        • Construction Polycarbonate enclosure
        • Colour Light grey & blue
        • Environment IP 67 (IEC 529)
        • Operating temperature -15°C to + 85°C

        Yes! I am Interested
        Request CallBack
        ESE Lightning Arresters
        Ask For Price

        ESE Lightning Arresters

        Product Details:
        Arrester TypeStation Type, Intermediate Type, Distribution Type
        BrandLPI
        MaterialCopper, Copper-Clad Steel, Aluminum
        Lightning is one of the most devastating natural phenomena. There are many discharges during lightning storms and some of them can even reach hundreds of kilo amperes. The electrical discharges are a great hazard to people, animal, buildings and electronic equipments. The economic consequences of lightning are also very important; it can cause fire, stop production of a factory or interrupt critical processes. A direct lightning discharge lasts a very short time but the intensity is enough to provoke electrocution resulting in heart failure and causing burns of different degrees to the human beings. Lightning is a constant hazard where the buildings and equipments are becoming more complex and sensitive every day. One lightning strike discharge can damage the buildings and cause failures to the electronic devices inside the building and sometimes it may even results in fire and important economical losses. Until now, there is no device that can prevent lightning formation or lightning strikes. However, it is possible to create a path (divert) for the lightning discharge to the ground which will minimise the damage to the environment through a well designed Lightning Protection System (LPS). The lightning protection should be considered preferably during the initial stage of the building/structure design which has 4 basic objectives:
        During the formation of a cumulonimbus (cloud forming a towering mass with a flat base at fairly low altitude and often a flat top, as in thunderstorms), there is an increase of ionisation and a potential difference is generated between the thunder cloud and the ground, which gives rise to small discharges. As the electric field gains in strength, the descending leader breaks up the dielectric field in the air. Ultimately, this may break through the layers of dielectric field in the air and strike the surface via the upward propagating tracer from the surface. In normal conditions there is a balance between positive and negative charges in the atmosphere, where the ground is more negatively charged than the air and the elements placed on the ground. However, the formation of storm clouds creates a charge polarization; usually, the lower part of the cloud is charged negatively, inducing then a positive charge at the ground and other elements on it. The electric field at the atmosphere can reach kilovolts in a short span of time. When the electric field is high enough, the cloud starts discharging towards the ground. The path formed by this discharge is called “downward leader” and produces a very sharp variation of the electric field, causing the corona effect. One of these objects/structure will be forming the upward leader, which will move towards the downward leader thus forming the discharge path between the cloud and the ground.

        This object/structure will be hit with the lightning strike. The cloud charge will try to find the straightest/shortest path to earth and if this path is not controlled, damages can be severe. Electrical effects: Damages/destruction to the electrical & electronic equipments. Abnormal rise in ground voltage and surges/transients can damage all the equipment connected to the electrical network.

        Electrodynamical effects: Structure/building damages. The conductors & equipments which falls within the vicinity of the flow of lightning current are submitted to mechanical strengths due to the magnetic field originated. This may cause deformations and rupture the conductors & equipments.

        Yes! I am Interested
        Request CallBack
        SPC PV 1000 Lightning Arrester
        Get Best Quote
        Approx.
        Rs 2,500
        Per Unit

        SPC PV 1000 Lightning Arrester

        Product Details:
        Minimum Order Quantity1 Unit
        BrandHakel
        ColorBlue
        Voltage Rating7kV-500kV
        Weight900 g
        Lifetimemin.100 000 h
        SPC PV-1000 is Lightning Arresters type 1+2 according to EN 61643-11. It is designed for protection of positive and negative busbars of photovoltaic systems against the surge effects. These arresters are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0-1 (according to IEC 1312-1and EN 62305). Particular varistor sectors connected between terminals L+, L- and PE are equipped with fitted internal disconnectors which are activated when varistors fail (overheat). Failure indication of these disconnectors is partly mechanical (by red signaling target) and partly remote monitoring (by potential free switching contacts).

        Yes! I am Interested
        View PDF
        Request CallBack
        SPC PV 600 DS Lightning Arresters
        Get Best Quote
        Approx.
        Rs 11,200
        Per Set

        SPC PV 600 DS Lightning Arresters

        Product Details:
        Arrester TypeStation Type, Intermediate Type, Distribution Type
        BrandHakel
        Weight900 g
        Specifications:
        • Max. continuous operating voltage UC 255 V AC
        • Lightning impulse current (10/350) Iimp 110 kA Nominal impulse discharge current (8/20) In 50 kA Voltage protection level Up< 2,5 kV Max. back-up fuse 500 AgL/gG

        Yes! I am Interested
        Request CallBack
        SPC PV 800 DS Lightning Arrester
        Get Best Quote
        Approx.
        Rs 9,500
        Per Unit

        SPC PV 800 DS Lightning Arrester

        Product Details:
        Arrester TypeIntermediate Type, Distribution Type
        Weight900 g
        Lifetimemin.100 000 h
        Degree of protection of enclosureIP20
        SPC PV 800 DS is a lightning and surge arrester type 1+2 according to IEC EN 61643-11 and EN 50539-11. It is designed for protection of positive and negative busbars of photovoltaic systems against the surge effects. These arresters are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0-2 (according to IEC EN 62305). Particular varistor sectors are equipped with internal disconnectors, which are activated when the varistors fail (overheat). Operational status indication of these disconnectors is partly mechanical (by exserted red signaling target in case of failure) and partly remote monitoring (by potential free change over contacts – only DS types).

        We are considered in the market to be one of the leading manufacturers and suppliers of this highly commendable range of Lightning Arrester.

        Yes! I am Interested
        Request CallBack
        SPC PV 600 Lightning Arresters
        Get Best Quote
        Approx.
        Rs 10,200
        Per Set

        SPC PV 600 Lightning Arresters

        Product Details:
        BrandHakel
        Housing TypePolymer
        Voltage5kV-500kV
        SeriesSPC PV 600
        We are offering SPC PV 600 Lightning Arresters.

        Yes! I am Interested
        X
        Looking for “Lightning Arrester”?